Skip to product information

SQ174 Pneumatic Body Massager with 5 Interchangeable Heads

The SQ174 uses adjustable pneumatic pulses for body massage. Five interchangeable heads, a touchscreen and 1–21 Hz settings make sessions easy to tailor.

$1,905.00 AUD Global Free Shipping
Plug Option: AU Plug
Product subtotal: $1,905.00 AUD
We accept:
  • Visa
  • Mastercard
  • American Express
  • PayPal
  • Apple Pay
  • Google Pay
Secure checkout
Free shipping
30-day returns
1-year main-unit warranty

Ships in 1–3 business days Delivery estimates shown at checkout

Questions before ordering? Talk to a product specialist
SQ174 Pneumatic Body Massager with 5 Interchangeable Heads
Regular price $1,905.00 AUD
Regular price Sale price $1,905.00 AUD
Plug Option: AU Plug
SQ174 Pneumatic Body Massager with 5 Interchangeable Heads
SQ174 Pneumatic Body Massager with 5 Interchangeable Heads
$1,905.00 AUD Global Free Shipping
SQ174 Pneumatic Body Massager with 5 Interchangeable Heads product view
PNEUMATIC · BALLISTIC SHOCKWAVE

SQ174 Pneumatic Shockwave Massager

A compressor-driven body massage machine that turns high-energy pneumatic pulses into precise ballistic shock waves. Five interchangeable impact heads, a touchscreen console and fully adjustable frequency and pressure cover shoulder, back, hip, leg and arm work from one compact unit.

5 Impact Heads 1–21 Hz 0.5–10 Bar Touchscreen

Powered by Air, Not Vibration Motors

At the heart of the SQ174 is a built-in compressor that generates high-energy pneumatic pulses. Instead of the surface buzz of an ordinary massage gun, each pulse travels down the handle as a mechanical wave — steady, countable and adjustable strike by strike.

Built-in compressor High-energy pneumatic pulses

Transformed into Ballistic Shock Waves

Inside the handle, a bullet body is driven back and forth by the pulses, converting them into precise ballistic shock waves that travel through the impact head into the body. A thin layer of gel on the skin helps the wave couple smoothly into the tissue.

Ballistic transmission Gel-assisted coupling

Five Impact Heads, One for Every Area

Each head threads on and off in seconds — clockwise to tighten, counter-clockwise to release. Match the head to the area: #1 small head for hands, wrists and ankles; #2 flat head for elbows and superficial muscle; #3 protruding head for knees, deep joints and soles; #4 medium head for shoulders, spine sides, waist and back; #5 large head for the back, hips and other large areas.

Twist-on, twist-off #1–#5 area matched
SQ174 five interchangeable impact heads — #1 small, #2 flat, #3 protruding, #4 medium and #5 large

One-Touch Screen Control

Power on, tap the welcome screen, pick the body area, and the console suggests the right impact heads for it. Every parameter — frequency, energy, strike count — is adjusted on the same clear panel, so a new operator can get started in minutes.

Guided area selection Suggested head display
SQ174 touchscreen one-click operation with welcome interface

Every Strike Counted and Adjustable

The function menu shows work time, a preset strike target (Preselection) and the running count (Current) — the machine prompts automatically when the target is reached. Frequency adjusts from 1 to 21 Hz, energy from 0.5 to 10.0 bar, and a lifetime counter (NUMBER OF TIMES) tracks every strike for maintenance planning.

1–21 Hz · default 1 Hz 0.5–10.0 bar · default 0.5 Preset + current + total counters

Full-Body Massage Coverage

Shoulder, back, abdomen, hip, leg and arm — one machine covers the full body menu of a salon or home care routine. Swap heads as you move between areas and keep the head flat against the skin; the handle button only activates while the head is in contact.

6 body areas Contact-activated handle
SQ174 full body massage coverage — shoulder, back, abdomen, hip, leg and arm

A Session in Three Steps

1 · Prep & Select

Cleanse the skin, thread on the impact head for the area, and apply a small amount of gel if desired. Select the area on the touchscreen.

2 · Set Low, Build Up

Start at the default 1 Hz and 0.5 bar, then increase frequency and energy gradually to the client's comfort.

3 · Contact & Count

Place the head flat on the skin, tap START on screen and press the handle button. The machine counts every strike and prompts when the preset target is done.

Maintenance reminders from the manual: empty the filter cup at the back of the machine before each use; the bullet body lasts about 2 million strikes and the system prompts automatically when it is due; replace the impact head when its dent exceeds 2 mm; pause the machine and unplug the handle cable before swapping heads.

What's in the Box

Main console × 1 · shockwave handle with control button × 1 · impact heads #1–#5 (small / flat / protruding / medium / large) · power cord × 1 · user manual × 1

Specifications

Product Name Pneumatic Shock Wave Massager
Model SQ174
Working Principle Compressor-driven pneumatic pulses converted into ballistic shock waves
Frequency 1–21 Hz (default 1 Hz)
Energy (Pressure) 0.5–10.0 bar (default 0.5 bar)
Impact Heads 5 interchangeable heads: #1 small / #2 flat / #3 protruding / #4 medium / #5 large
Display Touchscreen LCD — work time, preset strike count, current count, total strike counter
Wear-Part Life Bullet body ≈ 2 million strikes (auto prompt); bullet head ≈ 1 million; rubber pad ≈ 300,000
Voltage 110–240V, 50/60Hz
Device Size 40 × 30 × 25 cm
Net Weight About 9.5 kg
Material ABS
Fuse 10A (5 × 20 mm)
Plug Type US / EU / UK / AU Plug
Warranty Main unit 1 year (free service for faults under normal use)

The device is a cosmetic beauty device, not medical equipment.

FAQ

What is this machine designed for?
It is a cosmetic body massage device for salon and home care. A built-in compressor generates pneumatic pulses that the handle converts into ballistic shock waves, delivered through five interchangeable impact heads — all controlled from one touchscreen.
How do I set frequency and energy?
Frequency adjusts from 1 to 21 Hz (default 1 Hz) and energy from 0.5 to 10.0 bar (default 0.5 bar) on the function menu. The manual recommends starting low and increasing gradually to the client's comfort.
Which head should I use on which area?
#1 small head — hands, wrists, ankles; #2 flat head — elbows and superficial muscle; #3 protruding head — knees, deep joints, soles; #4 medium head — shoulders, spine sides, waist and back; #5 large head — back, hips and other large areas. The touchscreen also suggests heads after you pick a body area.
What maintenance do the wear parts need?
The bullet body lasts about 2 million strikes — the system prompts automatically when replacement is due. The bullet head lasts about 1 million strikes and the rubber pad about 300,000. Replace an impact head when its dent exceeds 2 mm, and empty the filter cup at the back of the machine before each use.
Who should not use it?
Pregnant, lactating or menstruating women; anyone with implanted metal or electronic devices (cardiac pacemakers, defibrillators, nerve stimulators, drug pumps); people with malignant tumors, heart disease, arrhythmia, epilepsy, severe hypertension or diabetes; areas with artificial fillers or skin wounds; clients recovering from major surgery. Avoid the ribs, wait at least one hour after a meal before abdominal work, and remove all metal items before a session.
What is included and what power does it need?
The console, shockwave handle with control button, five impact heads, power cord and user manual. It runs on 110–240V, 50/60Hz mains with a US / EU / UK / AU plug.

Disclaimer & Safety Notes

Disclaimer: This is a cosmetic beauty device, not medical equipment. It is only for aesthetic body care and massage use, not for disease diagnosis or treatment. Please use it correctly and stop use once discomfort occurs. All experiences vary by individual physical condition.

Product-specific safety notes (from the user manual):

✓ Prohibited users: pregnant, lactating or menstruating women; people with implanted metal or electronic devices (cardiac pacemakers, defibrillators, nerve stimulators, drug pumps); people with malignant tumors, heart disease, arrhythmia, epilepsy, severe hypertension or diabetes; clients recovering from major surgery; areas with artificial fillers or skin wounds must be avoided.

✓ Avoid the ribs during operation. Do not work the abdomen on a full stomach — wait at least one hour after a meal. Remove all metal items from the body and clothing before a session.

✓ The handle button activates only while the impact head is in close contact with the skin. Pause the machine and unplug the handle cable before replacing heads — never aim a running handle at sensitive parts of the body.

✓ Empty the filter cup at the back of the machine before each use; accumulated water can flow back and damage the air pump. Unclog the ballistic tube every two days with a brush dipped in lubricating oil.

✓ Leave at least 5 cm of space around the machine for ventilation; operate at 0–26 °C and below 80% relative humidity. Power off and unplug before replacing the 10A fuse. Do not use near short-wave or microwave equipment (keep at least 1 meter away).

International mains compatibility: 110–240 V AC.

Recently viewed products

Related products