SQ191 8-in-1 448 kHz Salon Beauty Machine
Turn one treatment station into a flexible salon menu. Eight purpose-built heads combine warming massage, vacuum body contouring, fascia care, red light and microcurrent for professional face-and-body routines.

Build more face-and-body services around one console
SQ191 brings eight purpose-built working heads together for slimming-focused body contouring, warming massage, fascia care and facial firming routines. Its touchscreen controls help salon professionals move between services without filling the treatment room with separate machines.
Designed for trained salon, spa and studio operators who want a flexible platform for both body and facial cosmetic care.
One organized station, multiple service directions
Body contouring & massage
Use the different-size vacuum heating heads, fascia tool and sculpting accessories for smoother-looking, better-defined body-care routines.
Warming 448 kHz care
CAP and RES contact options give trained operators two ways to add adjustable warming care to professional face-and-body protocols.
Facial finishing care
Red light and microcurrent functions support firming-focused, smoother-looking facial care without presenting the device as medical equipment.
What does each attachment do?
Eight distinct heads let the operator match contact size, sensation and technique to the chosen cosmetic area. Use only the combinations and settings described in the supplied manual.

Small vacuum heating head
Targeted suction and warmth for smaller permitted areas. Adjust suction and temperature gradually according to client comfort.

Large vacuum heating head
Broader body contact for massage and slimming-focused contouring routines on areas such as the waist, abdomen and thighs.

Red-light meridian brush
A multi-point body head for rhythmic massage-style care with red light, suited to larger body routines permitted by the manual.

Red-light microcurrent head
Combines a smooth contact surface with red light and adjustable microcurrent for facial or body firming-focused finishing care.

CAP ceramic probe
The capacitive contact option for controlled 448 kHz warming care. Select the correct accessory and return plate setup from the manual.

RES contact probe
The resistive contact option for professional warming and massage protocols, used with the supplied return plate as directed.

JMD fascia tool
A grip-style manual body tool for gliding massage, tissue-mobilizing movements and sculpting-focused body care.

Heating scraping bar
A long curved contact surface for broad, assisted body massage on suitable areas such as the back, waist and limbs.
448 kHz, CAP and RES—what do they mean?
CAP and RES are two contact methods used by the SQ191’s 448 kHz warming system. They are not separate promises of weight loss or medical treatment. Their different contact surfaces let a trained operator adapt the warming sensation and technique to the permitted cosmetic area.
The supplied stainless-steel return plate completes the operating circuit for compatible modes. Position it exactly as shown in the manual, keep full contact, remove metal accessories and begin at a conservative setting.

Match the head to the service area
Face and neck
- Red-light microcurrent finishing care
- Appropriate CAP or RES contact options where the manual permits
- Firming, smoothing and radiance-focused cosmetic routines
Body
- Waist, abdomen, thighs, arms and back
- Vacuum heating massage and fascia care
- Slimming-focused contouring and smoother-looking body care
Not every attachment is suitable for every area. Do not use vacuum, high heat or body tools on the face unless the supplied manual expressly permits it.
Plan the session before you start
- 01 · ConsultConfirm the cosmetic goal, screen contraindications, inspect the skin and remove metal accessories.
- 02 · PrepareSelect the correct head, contact medium and return plate arrangement described in the manual.
- 03 · Start lowSet time, energy, suction and heat conservatively; keep checking the client’s comfort and skin response.
- 04 · Finish & cleanReturn settings to zero, switch off, disconnect and sanitize compatible contact surfaces after every client.
At a glance
One console with a complete working set
Main system
SQ191 touchscreen console, power cord and working-head storage frame.
Eight working heads
Two vacuum heating heads, meridian brush, red-light microcurrent head, CAP probe, RES probe, fascia tool and heating scraping bar.
Operating accessories
Stainless-steel return plate, compatible replaceable contact pieces shown in the listing, and user manual.
Questions professionals ask
Is SQ191 intended for home use?
Its eight-head configuration, return-plate modes and adjustable heat, suction and energy make it better suited to trained salon, spa and studio operators.
Does 448 kHz guarantee slimming or fat loss?
No. SQ191 supports warming, massage and slimming-focused cosmetic body-contouring routines, but individual appearance results vary and no body-measurement outcome is guaranteed.
Are CAP and RES the same function?
They are two contact methods within the 448 kHz system. Their surfaces and operating feel differ, so use the matching probe, return plate and medium specified in the manual.
Can several heads operate at once?
Use only the operating combinations expressly supported by the supplied manual. Do not assume that all connected heads can run simultaneously.
What contact medium is required?
The required gel, cream or other coupling medium depends on the selected function. Follow the supplied manual rather than substituting a product that may damage the head or irritate skin.
Professional screening matters
SQ191 is a cosmetic beauty device, not a medical device. Do not use it for diagnosis or treatment. Do not use on broken, irritated or infected skin; over the eyes, front of the neck, heart area, bony prominences or other prohibited areas. Do not use on pregnant clients, minors, people with pacemakers or implanted electronic devices, internal metal near the intended area, serious uncontrolled health conditions, impaired heat sensation, or anyone contraindicated by the manual. Stop immediately if the client experiences pain, burning, dizziness, unusual discomfort or an unexpected skin reaction.